
ZX-E
Intelligens induktív mérőérzékelő
A ZX-E a legjobb megoldást kínálja a fémtárgyak pontos mérésére. Használata főként nagy igénybevétellel járó környezetben, például az autógyártásban és fémmegmunkáló gépek esetén ajánlott.
- Nagy felbontás (1 µm)
- Gyors válaszidő (150 µs)
- Könnyen cserélhető érzékelőfej
- Moduláris platformmegoldás a különböző érzékelési technológiák számára
- A linearitás egyszerű beállítása bármely fém esetén
Specifikáció és rendelési információ
Ordering information
Sensors
Sensor heads
, | ||||
Amplifier units
Note: Compatible connection with the sensor head.
Accessories (order separately)
Calculating unit
Amplifier mounting brackets
SmartMonitor sensor setup tool for Personal Computer connection
Cables with connectors on both ends (for extension)
*
undefined
* Robot cable models are also available. The model numbers are ZX-XC_R.
Specifications
Sensor heads
Magnetic metals |
||||||||
6
6.
Accuracy: The resolution is the deviation (
±3
σ) in the linear output when connected to the ZX-EDA amplifier unit. The above values indicate the deviations observed 30 minutes after the power is turned ON.
(The resolution is measured with Omron's standard reference object at ½ of the measurement range with the ZX-EDA set for the maximum average count of 4,096 per period.) The resolution is given at the repeat accuracy for a stationary workpiece, and is not an indication of the distance accuracy. The resolution may be adversely affected under strong electromagnetic fields. |
||||||||
(including amplifier unit) |
||||||||
1,000 VAC, 50/60 Hz for 1 min between charged parts and case |
||||||||
10 to 55 Hz with 1.5-mm double amplitude for 2 h each in X, Y, and Z directions |
||||||||
Amplifier units
2. Models with protective spiral tubes are also available. Add a suffix of “-S” to the above model numbers when ordering. (Example: ZX-ED01T-S)
6.
Accuracy: The resolution is the deviation (
±3
σ) in the linear output when connected to the ZX-EDA amplifier unit. The above values indicate the deviations observed 30 minutes after the power is turned ON.
(The resolution is measured with Omron's standard reference object at ½ of the measurement range with the ZX-EDA set for the maximum average count of 4,096 per period.)
The resolution is given at the repeat accuracy for a stationary workpiece, and is not an indication of the distance accuracy. The resolution may be adversely affected under strong electromagnetic fields.
7. Linearity: The linearity is given as the error in an ideal straight line displacement output when measuring the standard reference object. The linearity and measurement values vary with the object being measured.
9. Temperature characteristic: The temperature characteristic is measured with Omron's standard reference object at ½ of the measurement range.
12.
The response speed of the linear output is calculated as the measurement period x (average count setting + 1) (with fixed sensitivity).
The response speed of the judgement outputs is calculated as the measurement period x (average count setting + 1) (with fixed sensitivity).
2. Models with protective spiral tubes are also available. Add a suffix of “-S” to the above model numbers when ordering. (Example: ZX-ED01T-S)
6.
Accuracy: The resolution is the deviation (
±3
σ) in the linear output when connected to the ZX-EDA amplifier unit. The above values indicate the deviations observed 30 minutes after the power is turned ON.
(The resolution is measured with Omron's standard reference object at ½ of the measurement range with the ZX-EDA set for the maximum average count of 4,096 per period.)
The resolution is given at the repeat accuracy for a stationary workpiece, and is not an indication of the distance accuracy. The resolution may be adversely affected under strong electromagnetic fields.
7. Linearity: The linearity is given as the error in an ideal straight line displacement output when measuring the standard reference object. The linearity and measurement values vary with the object being measured.
9. Temperature characteristic: The temperature characteristic is measured with Omron's standard reference object at ½ of the measurement range.
12.
The response speed of the linear output is calculated as the measurement period x (average count setting + 1) (with fixed sensitivity).
The response speed of the judgement outputs is calculated as the measurement period x (average count setting + 1) (with fixed sensitivity).
Miben segíthetünk?
Ha kérdése van, vagy árajánlatot szeretne kérni, vegye fel velünk a kapcsolatot, vagy küldjön kérelmet.
Vegyék fel velem a kapcsolatot ZX-E

Köszönjük megkeresését. Hamarosan kapcsolatba lépünk Önnel.
Műszaki hiba lépett fel. Az űrlap adatai nem kerültek feldolgozásra. Elnézést kérünk ezért, kérjük próbálja meg később ismét. Részletek:[details]
DownloadIdézet a következőre: ZX-E
Az alábbi űrlap kitöltésével kérhet ajánlatot kiválasztott termékeinkről. A *-gal jelölt mezőket kérjük kitölteni. Adatait bizalmasan kezeljük.

Köszönjük érdeklődését. Hamarosan továbbítjuk Önnek a kért információt.
Műszaki hiba lépett fel. Az űrlap adatai nem kerültek feldolgozásra. Elnézést kérünk ezért, kérjük próbálja meg később ismét. Részletek:[details]
Download